Shorter Z up move between multiple probing attempts

For some probes like micro switches the full Z clearance raise between
probing attempts is not required while bigger Z clearance between probe
points is still needed to avoid clamps. The shorter Z raise within
multiprobing same point significantly increase probing speed and the whole
auto level process.
This commit is contained in:
nightgryphon
2018-07-09 12:25:52 +03:00
committed by Scott Lahteine
parent 3b5c81b84a
commit 54adf6f52d
4 changed files with 17 additions and 10 deletions

View File

@@ -496,7 +496,7 @@
* Set flags for enabled probes
*/
#define HAS_BED_PROBE (ENABLED(FIX_MOUNTED_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_PROBE || ENABLED(Z_PROBE_SLED) || ENABLED(SOLENOID_PROBE))
#define PROBE_SELECTED (HAS_BED_PROBE || ENABLED(PROBE_MANUALLY))
#define PROBE_SELECTED (HAS_BED_PROBE || ENABLED(PROBE_MANUALLY) || ENABLED(MESH_BED_LEVELING))
#if !HAS_BED_PROBE
// Clear probe pin settings when no probe is selected